Addressable Type Hooter Cum Strobe Specification

  • Sensor Life
  • Long-life electronic circuitry (> 10 years)
  • Voltage
  • 18V-28V DC
  • Suitable For
  • Industrial, commercial & residential fire alarm systems
  • Sensor Type
  • Addressable (electronics based)
  • Working Current
  • 30mA
  • Sensitivity
  • N/A (acts as output module, not detector)
  • Noise Level
  • 85-110 dB @ 1m (selectable)
  • Alarm startup time
  • 3 seconds
  • Wireless
  • No (wired addressable)
  • Sensor Cable
  • Fire survival cable or 2-core armored (as per design)
  • Control Distance
  • Up to 1.5 km on compatible addressable loop
  • Standby Current
  • 0.5mA
  • Alarm time
  • Continuous or as programmed by panel
  • Power Supply
  • 24V DC (from fire alarm panel)
  • Alarm Light Color
  • Red
  • Detection Range
  • Addressable, within protected area
  • Dimensions
  • 100mm x 100mm x 40mm (typical)
  • Color Options
  • Standard Red (strobe lens clear/red as per model)
  • Relative Humidity
  • 95% RH (non-condensing)
  • Body Material
  • ABS fire-retardant plastic
  • Wiring
  • 2-wire addressable loop
  • Weight
  • Approx. 170g
  • Mounting Type
  • Wall/Ceiling mount
  • Ingress Protection
  • IP30-IP43 (model dependent)
  • Product Certification
  • CE, EN54-3 compliant
  • Addressing Method
  • Soft addressing via hand-held programmer or panel
  • Operating Temperature
  • -10C to +55C
  • Strobe Flash Rate
  • 60-80 flashes per minute
 

Addressable Type Hooter Cum Strobe Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1000 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About Addressable Type Hooter Cum Strobe



Access the unassailable protection of the Addressable Type Hooter Cum Strobe, highly recommended for robust fire alarm systems in India. Its inestimable reliability is underscored by CE, EN54-3 certifications and superior ABS fire-retardant construction. Designed for both wall and ceiling mounting, this strobe boasts an IP30-IP43 ingress protection, supporting demanding environments. With soft-addressing for ease of setup, a long-life electronic circuitry (>10 years), and a 1.5 km control distance, this device ensures rapid, continuous alertness with 85-110 dB acoustic output, supported by a compelling promotion for industrial, commercial, and residential fire safety.

Versatile Protection in Commercial Spaces

The Addressable Type Hooter Cum Strobe is engineered for commercial, industrial, and residential applications, offering inestimable security with its superior ABS fire-retardant material. Its adaptable mounting options-wall or ceiling-ensure flexible installation. Certified for safety and designed to function across a wide temperature and humidity range, it is highly recommended for modern building safety infrastructures. Its 2-wire addressable loop ensures reliable alarm signaling, while selectable sound intensity and vivid strobe enhance emergency notification efficiency.


Sample Access, Export Offers, and Competitive Terms

We offer sample access for the Addressable Type Hooter Cum Strobe so you can evaluate its superior performance firsthand. Each unit is securely packaged, ensuring safe delivery across the export market, with promotions available for bulk orders. Our payment terms are flexible and competitive, making it easy for service providers, suppliers, and traders to benefit from our attractive rates. Contact us today to access these inestimable deals and elevate your fire alarm systems with unassailable quality.


FAQ's of Addressable Type Hooter Cum Strobe:


Q: How is the Addressable Type Hooter Cum Strobe installed in a fire alarm system?

A: The hooter cum strobe can be wall or ceiling mounted, using a 2-wire addressable loop. It is soft-addressed via a hand-held programmer or directly through the panel, ensuring straightforward integration with modern fire alarm networks.

Q: What are the main benefits of using this hooter cum strobe in commercial settings?

A: It delivers unassailable safety with reliable acoustic and visual alarms, supports large areas with control distances up to 1.5 km, and meets strict certifications (CE, EN54-3) for superior compliance-making it highly recommended for commercial premises.

Q: When should the strobe and hooter be activated?

A: Activation is programmed through the fire panel; upon receiving a fire alarm signal, the strobe flashes at a rate of 60-80 per minute and the hooter delivers a selectable sound level of 85-110 dB, ensuring prompt evacuation.

Q: Where can the Addressable Type Hooter Cum Strobe be used?

A: It is suitable for industrial, commercial, and residential buildings where reliable fire alerting systems are a necessity. Its robust design and compliance make it versatile across various environments.

Q: What materials and color options does the unit offer?

A: Constructed from ABS fire-retardant plastic, it is available in a standard red body with optional clear or red strobe lens, depending on the model. This ensures both durability and high visibility during alarms.

Q: Is there a sample available, and how does the product ship?

A: Yes, product samples are available for evaluation. Each hooter cum strobe is securely packaged for transport within India and for export markets, maintaining product integrity during shipping.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Equipments Category

Single Loop Card Fire Alarm Panel

Single Loop Card Fire Alarm Panel

Price 24750.0 INR / Unit

Minimum Order Quantity : 2 Units

Standby Current : 500mA

Alarm time : Continuous until reset

Sensor Cable : 2core, 1.5mm2 recommended

Wireless : Other, No (Wired loop)

Conventional Type Fire Alarm System

Conventional Type Fire Alarm System

Minimum Order Quantity : 10 Units

Standby Current : 0.1 mA (per detector)

Alarm time : Continues until reset

Sensor Cable : 2wire/4wire (shielded, up to 1.5 mm2)

Wireless : NO

Control Module For Fire Alarm System

Control Module For Fire Alarm System

Minimum Order Quantity : 10 Units

Standby Current : 0.8 mA

Alarm time : Adjustable

Sensor Cable : 2wire/4wire

Wireless : NO

Conventional Type Smoke Detectors

Conventional Type Smoke Detectors

Minimum Order Quantity : 10 Units

Standby Current : 24A

Alarm time : Continuous until smoke clears or reset

Sensor Cable : 2wire, nonpolarized

Wireless : NO



Back to top