16 Zone Fire Alarm Panel
16 Zone Fire Alarm Panel

16 Zone Fire Alarm Panel

MOQ : 10 Units

16 Zone Fire Alarm Panel Specification

  • Suitable For
  • Multi-zone commercial and industrial premises
  • Standby Current
  • Less than 200mA
  • Alarm startup time
  • Within 3 seconds
  • Wireless
  • No, wired panel
  • Sensor Type
  • Compatible with smoke, heat, and flame detectors
  • Working Current
  • Less than 500mA
  • Wireless Distance
  • Not applicable (wired system)
  • Voltage
  • 24V DC (internal circuits)
  • Sensor Life
  • 5-10 years (depending on type and environment)
  • Alarm Density
  • 0.65~2.5%/ft (for smoke detectors)
  • Noise Level
  • Less than 85 dB (panel operation)
  • Alarm time
  • Continuous until manually reset
  • Control Distance
  • Up to 1 kilometer (using dedicated fire cable)
  • Sensor Cable
  • 2-core, 1.5mm2 shielded fire cable recommended
  • Sensitivity
  • Adjustable per channel, compliant with EN54
  • Power Supply
  • AC 220V 10%, 50Hz
  • Alarm Light Color
  • Red
  • Remote Control
  • Supported via wired control panel interface
  • Detection Range
  • Up to 100 meters (open area)
  • Programming
  • Manual via front control panel
  • System Supervision
  • Automatic zone, battery, and cable supervision
  • Event Log
  • Stores up to 99 recent events
  • Reset
  • Manual push-button and remote reset input
  • Sounder Circuit
  • 2 supervised outputs, max 500mA each
  • User Interface
  • Push-button controls, LCD/LED indicators
  • Operation Temperature
  • -10C to +55C
  • Dimensions
  • Approx. 400mm x 300mm x 100mm
  • Panel Material
  • Metal body with powder coating
  • Battery Backup
  • Built-in, supports 2 x 12V 7Ah batteries (not included)
  • Humidity Range
  • 95% RH (non-condensing)
  • Zone Display
  • Individual LED indicators for each zone
  • Number of Zones
  • 16 independent zones
  • Fault Indication
  • LED indicator and audible beep
  • Test Mode
  • Supported for maintenance
  • Mounting Type
  • Wall mounted
  • Weight
  • Approx. 5 kg
  • Outputs
  • Fire relay, fault relay, sounder outputs
 

16 Zone Fire Alarm Panel Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1000 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About 16 Zone Fire Alarm Panel



Experience grand protection and superior reliability with our 16 Zone Fire Alarm Panel, crafted for multi-zone commercial and industrial premises. With 16 fully independent zones, every area is efficiently monitored using individual LED indicators. The enlightened design features a robust metal body, powder coated for extended durability, and an intuitive LCD/LED user interface. Enjoy advanced system supervision, rapid alarm response, and extended event logging. Discount available! Buy now to secure your premises-get comprehensive fire safety at an exclusive price. Don't miss out-Get it now and ensure peace of mind!

Application Excellence and Versatile Features

The 16 Zone Fire Alarm Panel is ideally suited for warehouses, factories, large office buildings, and other multi-zone premises. Its general use extends to commercial and industrial fire safety, supporting integration with smoke, heat, and flame detectors. Notable features include a built-in battery backup, automatic supervision for zones and cables, and test mode for maintenance. Its robust performance and dedicated outputs make it a reliable centerpiece for any fire detection system, ensuring critical safety across diverse environments.


FOB Port, Packing, and Certification Details

Goods transport of the 16 Zone Fire Alarm Panel is managed via major FOB ports across India, ensuring rapid logistics and efficient delivery. Packing & dispatch are performed with utmost care, using secure materials to prevent transit damage. Sample policy allows for inspection before bulk orders. Certified for EN54 compliance, this product guarantees quality and reliability in line with industry standards. Trust our seamless logistics and commitment to authenticated goods for your fire safety needs.


FAQ's of 16 Zone Fire Alarm Panel:


Q: How does the 16 Zone Fire Alarm Panel indicate a fire or fault in each zone?

A: Each of the 16 independent zones has its own dedicated LED indicator, which illuminates if a fire or fault is detected, accompanied by an audible beep for immediate attention.

Q: What types of detectors are compatible with this panel?

A: The panel supports smoke, heat, and flame detectors, making it versatile for various fire detection environments. Sensitivity for each channel can be individually adjusted per EN54 compliance.

Q: Where can this fire alarm panel be installed?

A: It's suitable for wall mounting in commercial and industrial premises, such as factories, warehouses, and office buildings, requiring multi-zone fire safety supervision.

Q: What is the process for resetting the alarm after activation?

A: You can reset the alarm manually with a push-button on the front panel or via a remote reset input, ensuring the system is ready for continued protection.

Q: When should maintenance or testing be performed on the panel?

A: Regular maintenance is recommended to ensure optimal performance. The panel features a dedicated test mode for convenient routine testing and inspection by authorized personnel.

Q: What are the logistics and certifications associated with this product?

A: The panel is dispatched securely via major Indian FOB ports following industry-standard packing. It is EN54 certified, assuring safety, reliability, and compliance with international fire safety guidelines.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Equipments Category

4 Loop Card Fire Alarm Panel

4 Loop Card Fire Alarm Panel

Minimum Order Quantity : 10 Units

Sensor Cable : Twisted pair, 1.5 mm2 recommended

Voltage : 24V DC (internal circuits)

Suitable For : Other, Industrial buildings, commercial complexes, hospitals, large offices

Wireless : Other, No (wired loop type)

Control Distance : Up to 1 km with repeater support

Addressable Type Fire Alarm Panel

Addressable Type Fire Alarm Panel

Minimum Order Quantity : 10 Units

Sensor Cable : Twisted pair, shielded (RS485/2core)

Voltage : 24V DC (internal power bus)

Suitable For : Other, Offices, Factories, Warehouses, Commercial Buildings

Wireless : Other, No (wired addressable system)

Control Distance : Up to 2 Km with looped cable system

8 Zone Fire Alarm Panel

8 Zone Fire Alarm Panel

Minimum Order Quantity : 10 Units

Sensor Cable : 2core or 4core firerated cable

Voltage : DC 24V internal circuitry

Suitable For : Other, Commercial buildings, Offices, Hospitals, Factories

Wireless : Other, No, wired system

Control Distance : Over 800 meters with standard cable

Isollation Module For Addressable Type System

Isollation Module For Addressable Type System

Minimum Order Quantity : 10 Units

Sensor Cable : 2wire loop, 1.02.5mm2 recommended

Voltage : 24V DC nominal (1830V DC operating range)

Suitable For : Other, Intelligent/Addressable Fire Alarm Systems

Wireless : NO

Control Distance : Dependent on system design, typically up to 1.5 km



Back to top